GB

• Collector box

• Two running wheels and two adjust-

able feet with assembly material

• Spanner

• Allen key

• Pusher

See the front fold-out page for il-

lustrations.

Overview

A

1 Wheels

2 Collector box

3 Safety switch

4 Shredder unit

5 Mains cable with strain relief

6 Transport handle

7 Reset switch

8 Funnel feeder

9 Operating mode selection switch

10 Pusher

11 Adjustor screw

12 Chassis

13 Supports

Functional description

The silent shredder is equipped with a power-

ful motor and motor brake, overload protec-

tion with an auto-reverse system, and restart

prevention for additional safety. A blade cyl-

inder system is used for cutting, which works

extremely quietly and automatically draws

in the shredding material. The sturdy chassis

ensures a stable standing position with good

mobility.

Refer to the following descriptions for a

functional description of the controls.

Technical data

Silent shredder ........... FLH 2800 A1

Nominal power intake

.........................2800 W (S6 40% 50s)*

Nominal voltage ...220V-240V AC, 50 Hz

Safety class ..................................... II

Degree of protection ........................ IP24

Branch thickness ...............Max 42 mm**

Collector box content .............Approx 60 l

Weight ........................................ 22 kg

Sound pressure level (L

pA

)

.................... 71,7 dB(A); K

pA

= 2,4 dB(A)

Sound power level

Measured (L

WA

)

....................91,7 dB(A); K

wA

= 2,4 dB(A)

Guaranteed ..................................94 dB(A)

* Continuous-operation periodic duty

(20 s on - 30 s idle)

*

*

The max. branch thickness that can be

chaffed is dependent on the type of

wood and the quality of the goods be-

ing cut.

For hard wood (e.g. oak/beech

branches), the max. branch thickness

that can be chaffed is less than for soft

wood (e.g. pine/spruce wood). For

dry or knotted wood, the cutting thick-

ness may also be less.

The sound levels have been determined in

accordance with noise measuring process

EN 13683:2009-09, appendix F.

Do not exceed the maximum authorised

network impedance of 0.28 Ohms at the

electrical connection point.

If necessary, confirm with your electric-

ity supplier regarding adherence to this

requirement.