CHAPTER 8: DEBUGGER

186

EPSON

S5U1C63000A MANUAL

(S1C63 FAMILY ASSEMBLER PACKAGE)

bc / bpc

(break point clear)

Function

This command clears the specified breakpoints that have been set.

Format

>bc [<break1> [ . . .<break16>]]

(direct input mode)

<break1–16>: Break address; hexadecimal or symbol (IEEE-695 format only)

Examples

>bp

1: 0116

... Breakpoints that have been set.

2: 0200
3: 0260
1. set 2. clear 3. clear all ...?

>bc 200

... Clears breakpoints at address 0x0200.

>bp

1: 0116
2: 0260
1. set 2. clear 3. clear all ...?

>bc

... Clears all breakpoints.

>bp

No PC break is set.
1. set 2. clear 3. clear all ...?

>

Notes

• The bc and bpc commands have the same functions.

• If no address parameter is specified, all the breakpoints that have been set are cleared.

• The format of parameters is same as the bp command. You can also use the guidance input mode of bp

command to do the same operation.

• You can use this command for multiple times to clear breakpoints.

• An error results if an address that is not set at a breakpoint is specified.

Error : Input address does not exist

GUI utility

[Break | Breakpoint Set …] menu item

When this menu item is selected, a dialog box appears for clearing breakpoints. (See the bp com-
mand.)

[Break] button

When this button is clicked after placing the cursor to a break address line in the [Source] window, the
breakpoint is cleared. If the address has not been set as a breakpoint, this button sets a new breakpoint
at the address.

[Break] button