Routine cleaning and maintenance – Enviro 50-1573 User Manual

Page 11

Advertising
background image

11

Routine Cleaning and Maintenance

If the glass has build up that can not be removed with only the cloth, clean the glass using paper towel

and a gas appliance glass cleaner, this may be purchased through most dealers. If a gas appliance glass

cleaner is not available, use a damp paper towel dipped in fly ash to clean the glass. After the glass has

been cleaned use the dry soft cloth to wiping down the outside and inside of the glass.

ASH PAN AND DOOR GASKETS (weekly)
After extended use the gasketing may come loose. To repair this, glue the gasketing on using high-

temperature fiberglass gasket glue available from your local dealer. This is important to maintain an

airtight assembly.

Figure 10: Pulling Ash Pan Out.

PELLET FUEL IN ASH PAN.

EXHAUST PASSAGES (biannually)
Removal of the firebox backing for biannual cleaning

• Open the door by lifting the handle, remove the

burn pot and burn pot liner.

• Lubricate all screws with penetrating oil.

• Remove the four (4) screws that hold the side panels

in place.

• With the tip of a flat screwdriver, gently lift up the

side panels and remove the side panels.

• Pull the center panel out.

• Vacuum thoroughly.
Installation of firebox backing:

• Insert center panel.

• Place the side panels back into the firebox and re-

install the two (2) screws on each side.

• Replace the glass door and secure.

• Clean thoroughly.

ASH PAN (weekly)
IMPORTANT: The unit must be OFF while the ash pan

is removed. Sweep the ashes from the firebox through

the grate into the ash pan.
The ash pan is located, in the pedestal, and has a

latching mechanism to secure it. To remove the ash

pan open the cover from the right hand side, unlock

the latch on the pedestal cover and pull the pan out. If

the ash pan is hot and/or dirty, gloves should be worn

to remove it. Pull the ash pan out. When the ash pan

is out of the unit lift the ash pan by the front and back

handles and carry the ash pan to where the ashes will

be emptied.

Vacuum inside ash box

Heat exchanger tubes

cleaner handle.

Figure 11: Evolution Open.

Dump the ashes into a metal container stored away from combustibles. Monitor the ash level every week.

Remember that different pellet fuels will have different ash contents. Ash content is a good indication of

fuel efficiency and quality. Refer to “S

AFETY

W

ARNINGS

A

ND

R

ECOMMENDATIONS

” for disposal of ashes. Vacuum

the inside of the ash pan compartment inside the pedestal including the hole at the top back of the

compartment. Replace the ash pan and close pedestal door. DO NOT PLACE UNBURNED OR RAW