Operating your pellet stove, Operating instructions – Enviro 50-1573 User Manual

Page 8

Advertising
background image

O

PERATING

Y

OUR

P

ELLET

S

TOVE

:

DO NOT OPERATE THE UNIT WITH THE DOOR OR ASH PAN OPEN. Keep hopper lid closed

except during re-fuelling.
CAUTION:
When operating during adverse weather, such as high winds or freezing rain, if the unit

exhibits dramatic changes in combustion stop using the unit immediately. Watch for blocked exhaust

outlet.
PRE-BURN CHECK: The burn pot liner holes must be clear and the liner installed properly against the

ignitor tube. Check the hopper for enough pellets to start the unit.

Figure 3: Thermostat Switch in

MANUAL position.

Figure 4: Thermostat Switch in

HIGH/LOW position.

 







 







1

2

3

4

5

6

7

8

9

 







 







 







 







1

2

3

4

5

6

7

8

9

 







 







Figure 5: Thermostat Switch in

AUTO/OFF position.

 







 







1

2

3

4

5

6

7

8

9

 







 







Note: The thermostat mode can be changed during normal

operation.
MANUAL MODE:
All control of circuit board function is adjusted at the circuit board.
To START: Press the ON / OFF button. The stove will turn on. The

system light will flash. The Auger Light will flash with each pulse of the

auger (the Auger Feed Rate is pre-programmed during start-up). The

Heat Level Indicator will show the Heat Level that the stove will run at after start-up.
If this is the first time the unit has been started or the unit has run out of fuel, the auger will need to

be primed. Press the Manual Auger Feed button until fuel starts to drop into the Burn Pot Liner (see

“O

PERATING

I

NSTRUCTIONS

; C

ONTROL

B

OARD

F

UNCTIONS

”).

When a fire has been established, the System Light will turn solid and the convection blower will turn on

(after approximately 10 - 15 minutes), and the Auger Light will continue to flash to the corresponding

Heat Level setting.
To OPERATE: Press the Heat Level button to change the desired Heat Level Output setting.
The speed of the convection blower is controlled by the setting of the heat level. This blower can be

turned OFF by depressing the convection blower control button. For the best efficiency, the convection

blower should be left on at all times.
When operating on LOW HEAT LEVEL, the feed rate can be adjusted, using the auger trim, for different

quality fuels. These settings can be used if the fire keeps going out on low (poor quality fuel). Or if the

low setting is too hot for the room (see “O

PERATING

I

NSTRUCTIONS

; C

ONTROL

B

OARD

F

UNCTIONS

”).

HIGH/LOW MODE: (Requires a Thermostat or Timer)
INITIAL START-UP: See MANUAL MODE above.
OPERATION: When the thermostat calls for heat (contacts are

closed) the stove settings are adjustable as per Manual Mode. When

the thermostat contacts open, the HEAT LEVEL and Fans will drop

down to the LOW setting until the thermostat contacts close again.

*The LOW heat setting can be adjusted for different fuel qualities

(see “O

PERATING

I

NSTRUCTIONS

- C

ONTROL

B

OARD

F

UNCTIONS

”). The stove will

come back to the previous HEAT LEVEL setting when the thermostat

contacts close again.
AUTO/OFF MODE: (Requires a Thermostat or Timer)
INITIAL START-UP: See MANUAL MODE above.
OPERATION: When the thermostat contacts close, the unit will light

automatically. Once up to temperature, the stove operates the same as

Operating Instructions

8