User manual – Edimax Technology ES-5224RM EN User Manual

Page 186

Advertising
background image

User Manual

Publication date: July, 2006
Revision A2

180

del trap

Syntax
:
del trap <range>
Description:
To disable the trap of the events.
Argument:
<range>:del the range of trap, syntax 1,5-7
Possible value:
<range>: 1~21
Example:
(alarm-events)# del trap 1-3


set all

Syntax
:
set all <range>
Description:
To enable email, sms and trap of events.
Argument:
<range>:set the range of email, sms and trap of events, syntax 1,5-7
Possible value:
<range>: 1~21
Example:
(alarm-events)# set all 1-3


set email

Syntax
:
set email <range>
Description:
To enable the email of the events.
Argument:
<range>:set the range of email, syntax 1,5-7
Possible value:
<range>: 1~21
Example:
(alarm-events)# set email 1-3

Advertising