User manual – Edimax Technology ES-5224RM EN User Manual

Page 213

Advertising
background image

User Manual

Publication date: July, 2006

Revision A2

207

<<maintain>>

set aging

Syntax
:
set aging <time>
Description:
To set up the age out time of dynamic learning mac.
Argument:
<time> : Mac table ageout time between 10 and 1000000 seconds. The value “0”
means to disable age out time
Possible value:
<time> : 10-1000000 seconds or 0
Example:
(mac-table-maintain)# set aging 300



set learning

Syntax:
set learning <port> <num>
Description:
To set up the maximum amount of MAC that each port can learn.
Argument:
<port> : port range,

syntax 1,5-7, available form 1 to 24

<num>: MAC address numbers which can be dynamically learned

num range: between 0 to 8191; 0 for learning disabled

Possible value:
<port> : 1 to 24
<num>: 0 to 8191
Example:
(mac-table-maintain)# set learning 5 100



show

Syntax:
show
Description:
To display the settings of MAC table ageout time and the learning limit of each port.
Argument:
None.
Possible value:
None.

Advertising