5. DescriPtion of cHarGinG PHases

6. Maintenance

6.1 This charger requires no specific maintenance other

than cleaning which should be done with a dry cloth or a

tissue.

Do not use any solvents or cleaning agents on

the casing.

6.2 Ensure that the charger is unplugged from the mains

before installing or performing any maintenance.

NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.

iMPortant: No liability is accepted for incorrect use of this product.

Warranty: Guarantee is 12 months from purchase date, proof of which will be required for any claim.

inforMation: For a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.

01284 757500

01284 703534

[email protected]

sole uK Distributor, sealey Group,

Kempson Way, Suffolk Business Park

,

Bury St. Edmunds, Suffolk,

IP32 7AR

www.sealey.co.uk

Web

email

Original Language Version

SMC03.V2 Issue: 1 - 31/10/13

© Jack Sealey Limited

4.5

MoDe 3 DescriPtion (*14.7/4.0a)

4.5.1 This mode is mainly for charging large batteries with

a capacity over 14Ah in cold conditions or for charging

several AGM batteries with a capacity over 20Ah.

Press the MODE button until the LED adjacent to the

ice crystal symbol is illuminated. Charging will

automatically start with a set delay with a current of

3.8A ± 10% and the ‘charging’ LED will illuminate. This

LED will remain on throughout the entire charging

process until the battery is fully charged up to *14.7V

± 0.25V. At this stage the ‘charging’ LED will extinguish

and the ‘fully charged’ LED will illuminate. The trickle

charge current now becomes available for battery

maintenance.

4.6

MoDe 4 DescriPtion (7.5/4a)

4.6.1 This mode is mainly for charging all types of 6 volt

batteries with a capacity over 14Ah. Press the MODE

button until the LED adjacent to the 6V battery symbol

is illuminated. Charging will automatically start with a set

delay and the ‘charging’ LED will illuminate. This LED

will remain on throughout the entire charging process

until the battery is fully charged up to 7.5V ± 0.25V.

At this stage the ‘charging’ LED will extinguish and the

‘fully charged’ LED will illumniate. The trickle charge

current now becomes available for battery

maintenance.

4.7

MoDe 5 DescriPtion (cal)

4.7.1 This mode is for lead calcium or a battery below *10.5

volts with no capacity to absorb charging current, the

charger will automatically raise the output up to *17

volts. The Mode 5 LED will illuminate and flash, the

‘charging’ LED will illuminate. If the battery cannot be

recovered within 2 hours the “Fault”

(!) LED will

illuminate. The battery may require replacing.

4.8

fauLt Protection

4.8.1 In the case of a short circuit, open circuit, reversed

polarity or battery voltage below *7.5V ± 0.5, the

charger will turn off the electronic system and revert

to standby mode. Additionally the “Fault”

(!) LED will

illuminate. The fault must be identified and resolved

before any of the charging modes are initiated.

4.9

oVerHeatinG Protection

4.9.1 If the charger becomes too hot during the charging

process or due to extreme ambient temperatures the

power output is automatically reduced to a trickle

charge to protect the unit. Once the temperature drops

the charger will increase the power output automatically.

5.1 The

sMc03.V2 charger has a nine step fully automatic

charging cycle as shown in Fig.3 above, which is

indicative of the typical charging curve for a battery.

5.2 PHase 1 through 5 DiaGnosis & recoVery: As

soon as one of the charging modes is selected the

diagnostic function automatically detects the condition

of the battery i.e. voltage. If the voltage of a deeply

discharged battery is over *7.5V ± 0.5V the charger

begins to pulse charge with a small current to recover

it. Pulse charging ceases when the voltage reaches

*10.5V ± 0.5V. If the voltage detected is over *10.5V

± 0.5V the charger skips pulse charging and switches to

the preselected charging mode.

5.3 PHase 6 BuLK: Up to 80% of the charge is delivered

in this phase.

5.4 PHase 7 aBsorPtion: A constant low charging

current raises the voltage from *14.1V to 14.4V over a

period of time without gassing the battery. In this phase

complete charging up to almost 100% is achieved.

When full charge is reached the charger switches to

phase 8 and 9.

5.5 PHase 8 & 9 Maintenance cHarGe: If the battery

is loaded and/or the voltage across the terminals drops

below *12.8V, the charger starts a maintenance charging

pulse at a constant 0.8A until the voltage reaches *14.4V

at which point the maintenance charge is turned off. The

charger continues to monitor the battery condition and

will cycle between trickle charge and maintenance

charge indefinitely to keep the battery in peak condition.

The charger can be left connected to the battery in order

to perform this maintenance function.

note!

Figures marked thus * are for 12 volt batteries and

all figures are offered as a guide only. The charger is

automatic and requires no measurements by the user.

environmental Protection.

Recycle unwanted materials instead of disposing of them as

waste. All tools, accessories and packaging should be sorted,

taken to a recycle centre and disposed of in a manner which is

compatible with the environment.

When the product is no longer required, it must be disposed of

in an environmentally protective way.