The problem

The Cause

The Solution

Motor not turning

no power

Lift the on/off switch up to the 'on' position

Circuit breaker has tripped

Re-set circuit breaker.

Check that electrical connections are correct

Fuses burnt out

Replace fuse in plug and/or supply panel

Motor faulty / jammed

Inspect motor. Retern to authorised repair

agent if necessary

Motor will not start with nozzel closed / off

Insufficient voltage

Check that voltage is not more than 5%

below the nominal requirment

Low or no flow

Excessive suction pressure

Lower the height of the pump in respect to

the tank and / or increase the diameter of the

suction tube

Suction tube resting on bottom of tank

Raise suction tube

Low level in tank

Refill the tank

Air entering the suction tube or in the pump

Check all piping connections and the level of

fuel in the tank

Low rotation speed of motor

Check and adjust the motor voltage or use

cable with a larger cross section

Check valve blocked

Clean or replace

Tank filler clogged

Clean or replace the filter

Pump filter clogged

Clean or replace filter

Fluid leaks

Check all connections and the condition of

rubber tubes

Meter chamber obstructed

Clean the meter chamber

Meter not accurate enough

Air in the suction line

Check all seals and connections

Measuring chamber dirty

Clean the meter measuring chamber