Sealey TA101 User Manual

12 function digital automotive analyser, Ta101, Instructions for

Advertising
background image

1.1.

PERSONAL PRECAUTIONS

When using the analyser, please observe all normal safety rules concerning

:

Protection against the dangers of electric current.

Protection of the analyser against misuse.

Full compliance with safety standards can only be guaranteed if used with the test leads supplied. If necessary, these must be replaced with genuine

Sealey leads with the same electronic ratings. Failure to do so will invalidate the warranty.

DO NOT use leads if damaged or if the wire is bared in any way.

1.2.

GENERAL SAFETY INSTRUCTIONS

Familiarise yourself with the application and limitations of the analyser as well as the potential hazards. IF IN ANY DOUBT CONSULT A QUALIFIED ELECTRICIAN.

When the analyser is linked to a measurement circuit, do not touch unused analyser terminals.

When the scale of the value to be measured is unknown set the selector to the highest range available.

Before rotating the range selector to change functions, disconnect test leads from the circuit under test.

WARNING! Never perform resistance measurements on live circuits. Only measure on disconnected circuits.

Always be careful when working with voltages above 60V DC or 30V AC. Keep fingers behind the probe barriers whilst measuring.

When not in use, store the analyser carefully in a safe, dry, childproof location. Storage temperature range -10°C to 50°C.

Never apply voltage or current to the analyser that exceeds the specified maximum.

WARNING! Do not make current measurements on the 10A scale for longer than 10 seconds in every 15 minutes. Exceeding 10 seconds may cause damage

to the analyser and test leads.

T

he user shall ensure that test probes are correctly selected in order to prevent danger. Probes shall be selected to ensure that adequate barriers guard against

inadvertent hand contact with live conductors under test and that probes have minimal exposed probe tips. Where there is a risk of the probe tip short circuiting

with other live conductors under test, it is recommended that the exposed tip length shall not exceed 4mm.

INSTRUCTIONS FOR:

12 FUNCTION DIGITAL AUTOMOTIVE ANALYSER

MODEL No:

TA101

Functions

Function

Test Range

AC Voltage

326mV - 1000V

326Ω − 32.6MΩ

326µA - 10A

2cyl 180°- 8cyl 45°
0 - 3260rpm and

0 - 3260rpm x10

326µA - 10A

-20°C to 750°C

-4°F to 1400°F

0 - 99.9%

Typically 1mA

Durable bi-composite case and integral stand suitable for the toughest

workshop conditions. Large, hi-contrast LCD display with 18mm high

digital read-out and analogue bar graph. Includes auto-ranging,

data-hold, auto-polarity, auto-power-off and low battery display

functions. Bar graph simplifies lambda sensor testing. Supplied with

capped test probes and K-type thermocouple.

C o n n e c t i o n s

Frequency

Diode Test
Continuity Test

DC Current

AC Current

<50 Ohms
320Hz - 32kHz

T a c h o m e t e r

T e m p e r a t u r e

Duty Cycle

R e s i s t a n c e

Dwell Angle

3.26V - 750V

DC Voltage

V

RPM + COM

V

RPM + COM

µ

AmA / 10A + COM

V

RPM + COM

Display:

3 3/4 digits LCD display with a max. reading 3260. Digital height 18mm.

Polarity:

Auto polarity indication.

Measurement Rate:

3 times per second.

Over Range Indication: “OL” displayed on the LCD.

Low Battery Indication: The symbol is displayed when the battery voltage drops below the operating level.

Auto-Power- Off:

Analyser automatically shuts down after approx. 10 minutes of inactivity.

Press

“Hold” to switch on again.

Operating Environment: 0°C to 40°C (32°F to 104°F) at <75% relative humidity.

Storage Environment:

-10°C to 50°C (14°F to 122°F) at <75% relative humidity.

Power:

Single standard 9 Volt battery (PP3).

Fuse:

F10A/250V and F0.5A/250V.

Dimensions:

200 x 93 x 50 mm.

Weight Approx:

Approx. 400g including battery and holder.

1.

OFF Position

2.

AC/DC Voltage (+10)

3.

Resistance/Diode/Audible Continuity (+10)

4.

AC/DC Current (+10)

5. Frequency

6. Tachometer

7.

Duty Cycle

8. Temperature

9.

Dwell Angle

10. Select AC/DC/Resistance/Diode/Continuity

Function Guide (Fig.2)

Fig.1

Fig.2

Original Language Version

TA101 Issue No.3(L) - 16/06/14

IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE

PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR

PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.

Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these

instructions, and properly maintained, give you years of trouble free performance.

1. SAFETY

2. INTRODUCTION

© Jack Sealey Limited

Advertising
This manual is related to the following products: