Physical Characteristics

Function level:

B2

Maximum reading area:

74mm

×

105mm

Effective pixels:

592

×

840 dots at 200 dpi, 100%

Standard interface:

RS-232C serial
Bi-directional parallel

Optional interface:

(not available)

Serial interface protocols:

Transfer rate:

2400, 4800, 9600, and 19200 bps

Stop bit:

2 bits and 1 bit

Parity check:

None

Error Indications

Scanner errors are displayed on the control panel by a
combination of the ERROR and READY lights as shown below.

Error name

ERROR light

READY light

Command Error

On

On

Interface Error

Flashes

Off

Fatal Error

Flashes

Flashes

B-2