The condition data-block, B-17, Esc s – Epson GT-6500 EN User Manual

Page 199: Request condition) command, Scanner model technical data

Advertising
background image

Order of
bytes

Data
(in hex)

Contents

Explanation

48

52

‘‘R’’

Available resolution
(400 dpi)

49

90

400

50

01

51

41

‘‘A’’

Maximum reading area at the
maximum resolution and 100%
zoom
(main scan 3424 dots by sub
scan 4640 dots)

52

60

3424

53

0D

54

20

4640

55

12

*(xx denotes a variable)

The Condition Data-Block

The GT-4000 sends the following data-block when it receives the

ESC S

(Request condition) command.

Condition Data-Block

Order of
bytes

Data
(in hex)

Contents

Explanation

(Information block)

1

02

STX code

Header: indicates the beginning of
the data-block

2

xx*

Status

Status byte: indicates the status of
the scanner

3

1D

29 Bytes

Byte counter: indicates the number
of bytes of data

4

00

(Data)

1

43

‘‘C’’

Color mode

2

xx

i

3

52

‘‘R’’

Resolution

4

xx

n1

(main scan resolution)

5

xx

6

xx

n2

(sub scan resolution)

7

xx

8

41

‘‘A’’

Reading area

Scanner Model Technical Data

B-17

Advertising
This manual is related to the following products: