Serial communication, cont’d – Extron electronic Digital Video Scaler Series DVS 304 AD User Manual

Page 54

Advertising
background image

Serial Communication, cont’d

DVS 304 • Serial Communication

3-14

Command

ASCII Command

(host to scaler)

Response

(scaler to host)

Additional description

General Information

N

These commands are not case sensitive. Both (I) and (i) can be used interchangeably

I/i

Vid

X7!

• Aud

X7!

• Typ

X7#

• Std

X8!

• Pre

X8! X8! X8!

• Sdi

X7!

]

Query Firmware Version

N

These commands are not case sensitive. Both (Q) and (q) can be used interchangeably

Q/q

x.xx]

View the Firmware version.

Query Part Number

N

These commands are not case sensitive. Both (N) and (n) can be used interchangeably

N/n

60-736-01/-02
/-03/-04]

View the part number.

View Internal Temp.

20S

X8@

]

Internal temp. deg Celsius.

Front Panel Security Lockout (Executive Mode)

N

These commands are not case sensitive. Both (X) and (x) can be used interchangeably

Enable

1X/x

Exe1]

Limited front panel adjustments
only.

Disable

0x

Exe0]

Adjustments/selections can be
made from front panel.

View status

X

X8)

]

Show mode status.

(0= disabled, 1= enabled)

SDI Field Flip

Standard

73*0#

Flp 0]

Flip Fields

73*1#

Flp 1]

View

73#

Flp

X8)

]

(0= Standard, 1= Flipped)

Enhanced Mode

Set mode

52*

X%

#

Enh

X%

]

View mode

52#

Enh

X%

]

Refresh Lock

Enable

77*1#

RFl 1]

Disable

77*0#

RFl 0]

View status

77#

X8)

]

(0= Disabled, 1= Enabled)

Auto Memory

Enable

1M/m

Aut1]

Disable

0M/m

Aut0]

View status

M/m

X8)

]

(0= Disabled, 1= Enabled)

N

X%

= On/Off

0 = off/disable, 1 = on/enable

X7!

= Input selection

1 to 4

X7#

= Input video format

1 to 9 (see page 3-6)

X8)

= 0 or 1

X8!

= Input Standard:

0 = None, 1 = NTSC 3.58, 2 = PAL, 3 = NTSC 4.43, 4 = SECAM

X8@

= Internal temperature

(in degree Celsius)

Advertising