Equator WB 818 User Manual

Page 11

Advertising
background image

start or run.

● Motor (bad bearings or locked

rotor).

◇Replace motor.

Motor trips out on in

terminal thermal overload

protector.

●Start relay not dropping out.

●Improper voltage.

●Seal faces binding.

●Motor shaft binding.

●Motor windings shorted.

●Glass or foreign items in pump.

◇Replace start relay.

◇Check voltage.

◇Repair or replace.

◇Repair or replace.

◇Repair motor.

◇Clean and clear area.

Repeated dishwasher cycles

● Circuit board (contacts open or

burnt)

●

Motor (inoperative, check

resistances).

◇Replace circuit board.

◇Replace timer.

Dishwasher does not

advance automatically.

● Damaged circuit board.

●Check circuit for power ,check if

the wire misconnected.

●Have wire cut off

◇Replace circuit board.

◇ Reconnected wire and circuit

board .

◇Repair.

Dishwasher will not fill with

water.

●Water supply turns off.

●Defective inlet valve.

●

Check valve screen for

obstructions.

●Defective float switch.

●Damaged circuit board.

●Wiring (broken or burnt).

◇Turn water supply on.

◇Replace inlet valve.

◇Disassemble and clean screen.

◇Replace switch.

◇Replace circuit board .

◇Repair or replace.

Incomplete water fill.

●Low water pressure.

●Clogged water inlet valve screen.

● Heavy water supply usage

elsewhere in home.

●Kinked or restricted fill hose, water

inlet valve to fill tunnel.

◇ Minimum water pressure of

15P.S.I

◇Clean water inlet valve screen.

◇ Use dishwasher when water

usage is at a minimum.

◇Correct as needed.

Too much water fill.

●Water inlet fill valve defective.

● Damaged circuit board (open or

burnt).

● Float arm binding or out of

adjustment.

◇Replace water inlet fill valve.

◇Replace circuit board.

◇Repair, adjust or replace.

Dishwasher will not pump

out.

●Drain pump is restricted.

●Damaged impeller.

●Wiring or terminal (contacts open

or burnt).

◇Clear restrictions.

◇Replace drain pump.

◇Replace circuit board.

Water siphons out.

●Drain hose loop to low.

● Drain line connected to a floor

drain not vented.

◇Move to proper height.

◇Install vent air gap at counter

top.

Water leaks.

●Spray arm not rotating or split.

◇ Check for proper rotation or

replace spray arm.

11