Equator WB 818 User Manual

Page 13

Advertising
background image

●Defective seal on plunger.

●Over filling container.

◇Replace plunger.

◇ Follow instructions in owner’s

manual.

Noisy pump assembly.

●Impellers not properly shimmed or

rubbing.

●Pump parts not properly installed.

●Debris in bottom of tub sump area.

●Defective motor bearings.

◇ Use shim gauge furnished in

impeller and seal kit, when seals

are properly shimmed the

impellers will be in correct

operating position.

◇Inspect and correct.

◇Clean out sump area.

◇Replace motor.

Dishwasher continues to fill

or continues to fill even

though in case of there is no

voltage to fill valve.

● Something (dirt or foreign

material) under diaphragm in water

inlet valve.

●Defective water inlet fill valve.

◇ Clean water inlet valve or

replace.

◇Replace water inlet valve.

Detergent left in dispenser.

●Detergent cup held or blocked by

large dishes.

● Dispenser wet when detergent

was added.

◇On proper loading dishes.

◇Instructs customer/user.

Softener leaking

●Softener broken.

●Softener nut loosen.

◇Replace softener.

◇Screw down softener cap.

Leaking form air inlet.

●Air inlet nut loose.

●Air inlet install up side down.

◇Screw down air inlet nut.

◇Reinstall air inlet properly.

Window Display “E1”

●Inlet Valve Damaged.

●Inlet Valve Disconnected.

◇Replace Inlet Valve.

◇Reconnected Line.

Window Display “E2”

●Pressure Switch Damaged.

◇Replace Pressure Switch.

Window Display “E3”

●Heating Element (open).

●Power Supply To heating Element

Cutting.

◇Replace.

◇Reconnect Line.

Window Display “E4”

●Float Switch Act.

◇Take Remove The Rubber Cap

Let Water Pour Out.

Window Display “E5”

●Thermostat Sensor Damaged.

◇Replace sensor(See figure8).

13