14-ALARMS

Technical Dept. - All rights reserved - Reproduction is prohibited

ALARM ALERTS

In the event an operating anomaly occurs the stove starts switching off due to the alarm and informs the user of the type of

fault that has taken place via a 3 digit code which stays displayed on the rear emergency panel.

The alarm is indicated permanently by the relative 3 digit code, by a flashing red LED that lights up on the emergency panel and an

intermittent sound signal for the first 10 minutes of the alarm. Read the instructions in the following 2 paragraphs to cancel the alarm

status and restore the normal operating mode of the stove.

The following table describes the possible alarms indicated by the stove, associated to the respective code that appears on the emergency

panel and helpful tips to solve the problem.

MESSAGE ON DISPLAY

TYPE OF PROBLEM

SOLUTION

A01

The fire does not ignite

Check the level of pellets in the tank.

Check that the brazier rests correctly in its seat and has no

visible deposits of unburned pellets.

Check whether the ignition plug heats up.

A02

The flame is goes out unexpectedly

Check the level of pellets in the tank.

Check that the brazier rests correctly in its seat and has no

visible deposits of unburned pellets.

A03

The temperature of the pellet hopper

exceeds the required safety threshold.

The structure overheats due to reduced

heat dissipation.

The structure is too hot because the product has been

used for too long at the maximum power or there is poor

ventilation. When the product is sufficiently cold, press

button B on the control panel or OFF on the remote

control to cancel alarm A03. Once the alarm is cancelled,

the product can be switched on normally.

A04

The temperature of the exhaust smoke has

exceeded certain preset safety limits.

The stove switches off automatically. Let the stove cool

down for a few minutes and then switch it on again.

Check the smoke expulsion and the type of pellets used.

A05

Chimney flue clogged - wind - door open. Check the smoke duct and make sure the door is closed.

The smoke extractor fails to guarantee

sufficient primary air, required for correct

combustion.

Draught difficulties or brazier clogged.

Check whether the brazier is clogged and clean it, if

necessary.

Check and if necessary clean the smoke duct and air inlet.

A08

Abnormal operation of smoke fan

Check cleanliness of the fumes fan compartment and

check if dirt is blocking it. If this is not enough, the smoke

fan is faulty. Contact an authorised service centre to have

it replaced.

A09

The smoke probe is faulty and does not

detect the exhaust smoke temperature

properly.

Contact an authorised service centre to have the

component replaced.

A11

Pellet supply fault

Contact an authorised service centre to have the

component replaced.