Installation and fitting

Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited

3.6. COMBUSTION AIR AND AIR FILTER

The PowerSystem is equipped with a combustion air intake that

allows the intake of air that is essential to combustion. This

intake is located on the rear of the unit. It is equipped with a

pollen filter that can be easily cleaned. It is advisable to draw

combustion air from inside the room of installation and not from

outdoors. This will prevent intake of impurities, dust or

humidity.
The air filter is cylindrical. It is located just back of the unit at

the start of the tube. It is composed of a fine metallic mesh.
The filter must be regularly services. To reach it, the combustion

chamber must be extracted on its slides. To do this, refer to the

chapter on maintenance.

3.7. HOOD VENTILATION NOZZLES

3.7.1.

Introduction

The Powerbox can be used in two different ways:

• As an insertion in an existing cladding
• As a new installation


If the Powerbox is inserted in an existing cladding the ventilation grilles

on the cladding will be used.
If the Powerbox is used as a new installation, MCZ recommends

installing the ventilation nozzles as described in paragraph 3.9.2

3.7.2.

Hood ventilation nozzles for new cladding.

You must install MCZ ventilation nozzles, or nozzles

that ensure the same operation and the same air

passage cross section (see MCZ accessories).
MCZ non risponde di eventuali danni alla struttura o

alla componentistica elettrica causati dalla mancata

osservanza di questa avvertenza.


Because of the high power of the PowerBox, the structure reaches high

temperatures. Therefore, continuous and efficient ventilation must

always be ensured inside the cladding.
Besides ensuring perfect product operation, this action makes it

possible to recover part of the heat from the structure, which would be

wasted if it were left inside the cladding.
For better understanding of the number, size and function of the

ventilation nozzles to be installed on the cladding, the following are

some possible installation configurations with the relative nozzles.



Installation of standard nozzles for hood