Chapter 3

INSTALLATION AND USE MANUAL

page

25

Installation and fitting

Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited

IMPORTANT!

THE FAN MUST FACE AS SHOWN IN FIG.10NO
OTHER POSITIONS THAN THE ONE SHOWN ARE
PERMITTED.

IMPORTANT!

All electrical connections must be performed by
qualified personnel in accordance with current laws in
each nation, using suitable equipment and in
compliance with the diagram indicated in this booklet.
All operations must be performed with the 230V 50 Hz
mains power cord disconnected.

Mcz shall not be held liable for damage to persons or
things due to incorrect connections or improper use of
the device

3.11. MAKING THE ELECTRICAL CONNECTIONS

Connect the power cord to the back of the product first. Then connect
it to an electrical wall socket that is always accessible. If this is
not possible, during installation provide suitable devices for
disconnection from the power supply network, in compliance with
national standards on electrical systems.

Once the power supply has been connected and the whole installation
and cladding phase of the product completed, bring the switch (located
in the loading door) into position (I).

When not in use it is advisable to unplug the power
cord.

3.12. REALIZATION OF CLADDING

The product must be fully tested before the cladding
is placed. MCZ shall not be held liable for any
damage to the cladding if abnormal operation occurs
that were not checked before cladding the unit.

You MUST check the seal of all tubes where smoke
passes (smoke connection, gaskets and insertion in
flue pipe) before cladding.

BEFORE YOU START CLADDING OF THE UNIT, READ
CHAPTER 5.2 “OPERATING TEST”

To test operation of the product, temporarily install the door completed
with emergency panel and switch onto the pellet loading chute (see
chapter 3.14).

The fireplace stove and the parts of the cladding must be attached to
one another WITHOUT COMING INTO CONTACT WITH THE
STEEL STRUCTURE
to prevent transmission of the heat to the marble
and/or stone, and to allow normal thermal dilation. Use care with wood
finsihes such as crossbeams or shelves.

THERMAL PROTECTION OF CROSSBEAM

1.

Insulation applied or to be applied.

2.

Wood beam

3.

Marble or other material

1

1

3

10