TEMPORARY POWER CUT
If there is a power outage during operation, when the power
comes back on the stove will go into cooling mode and then it will
come back on automatically.
FAILURE TO LIGHT
If during ignition no flame develops, the stove will go into alarm
condition.
ANTI-FREEZE FUNCTION
If the probe in the boiler detects a water temperature of less than
5°C, the circulation pump is automatically activated to keep the
system from freezing.
PUMP ANTI-SEIZURE FUNCTION
If the pump is not used for prolonged periods, it is activated
periodically for 1 minute every 24 hours of inactivity to keep it from
seizing up.
TAMPERING WITH THE SAFETY DEVICES IS
PROHIBITED
It is only after eliminating the cause which gave rise to the
intervention of the safety system, that it is possible to relight
the stove and thus reset the automatic operation of the
sensor. To understand which anomaly has occurred, consult
this manual at paragraph 4.14 which explains what to do
based on the alarm message the stove displays.
ATTENTION
If the stove is not used as described in this instruction booklet,
the manufacturer refuses to accept any responsibility for
damage to persons and property that may arise. The
manufacturer furthermore refuses to accept responsibility for
damage to persons and property arising from the failure to
observe all the rules contained in the manual and in particular:
Failure when carrying out works of maintenance, cleaning
and repair to adopt all necessary measures and
precautions
Tampering with the safety devices.
Removing the safety devices.
Failure to connect the stove to an efficient system for the
discharge of smoke.
Failure to check in advance that the room where the stove
is to be installed is adequately ventilated.
4.18. ALARM SIGNALLING
Should an operation problem occur, the stove enters a shutdown phase
for alarm and informs the user of the type of fault that occurred using a
3 digit code that remains displayed on the control panel of the stove
(and a short description of the alarm type)
The table below describes the possible alarms signalled by the stove,
associated to the respective code that appears on the emergency panel,
and useful suggestions to solve the problem.
- Club HYDRO 15 kW High Efficiency Club HYDRO 15 kW Ver.2009 cod. 7109007 Club HYDRO 22 kW Club HYDRO 22 kW High Efficiency Ego HYDRO Ego HYDRO High Efficieny Musa HYDRO 15 kW Musa HYDRO 15 kW Ver.2009 cod. 7109008 Musa HYDRO 15 kW High Efficiency Musa HYDRO 22 kW Musa HYDRO 22 kW High Efficiency Star HYDRO Star HYDRO High Efficieny Suite HYDRO 15 kW Suite HYDRO 15 kW High Efficiency Suite HYDRO 15 kW Ver. 2009 cod. 7109007 Suite HYDRO 22 kW Suite HYDRO 22 kW High Efficiency