Chapter 5

INSTALLATION AND USE MANUAL

page

36

Maintenance and cleaning

Technical service - Rights reserved MCZ GROUP S.p.A. - Reproduction prohibited

6.2.2.

REPLACEMENT

OF

OVERPRESSURE

SILICON DAMPER FOR COMBUSTION CHAMBER


The overpressures sillicon damper "G" for combustion chamber (fig. A)

shall be replaced with a new one yearly (during the periodical

maintainance) in order to keep the overpressure safety system efficient.
For replacement use the following instructions

remove the top

remove the first lateral ceramic covering / metal covering (in

accordance with the model)

unscrew the screw-washer-damper-spacer shown in fig. A/C

(operate same way on both sides)

Install the new kit as follows:

Prepare the screw-washer-damper-spacer alligned as shown in

fig.C and screw them in the structure.

screw it completely
Check now the proper compression of dampers, using the gauge

included in the kit:

lay the gauge on the lid (fig.B); the gauge has to lay completely,

while the head of the screw has to be in contact with the gauge.
If it's not the case, register the screw accordingly.

A

B

C

G