Maintenance and cleaning
Technical service - Rights reserved MCZ GROUP S.p.A. - Reproduction prohibited
6.2.2.
REPLACEMENT
OF
OVERPRESSURE
SILICON DAMPER FOR COMBUSTION CHAMBER
The overpressures sillicon damper "G" for combustion chamber (fig. A)
shall be replaced with a new one yearly (during the periodical
maintainance) in order to keep the overpressure safety system efficient.
For replacement use the following instructions
remove the top
remove the first lateral ceramic covering / metal covering (in
accordance with the model)
unscrew the screw-washer-damper-spacer shown in fig. A/C
(operate same way on both sides)
Install the new kit as follows:
Prepare the screw-washer-damper-spacer alligned as shown in
fig.C and screw them in the structure.
screw it completely
Check now the proper compression of dampers, using the gauge
included in the kit:
lay the gauge on the lid (fig.B); the gauge has to lay completely,
while the head of the screw has to be in contact with the gauge.
If it's not the case, register the screw accordingly.