65

10-MAINTENANCE AND CLEANING

Technical Dept. - All rights reserved - Reproduction is prohibited

CLEANING THE SMOKE DUCT AND FITTING

When the product is extracted, you can intervene on the smoke fan (1) from the left side for cleaning and maintenance purposes. Clearly,

the smoke evacuation fan must be removed for such maintenance to be performed.

A gasket (3) is applied on the fan outlet, which guarantees the tightness with the smoke fitting (2). Always verify that this gasket is

intact and if necessary, replace it. The gasket can also be adjusted via a screw. The pressure on the fitting can be increased or decreased

by loosening the screw.

The flue connection to its ash collection compartment (4) is located in the rear/lateral part of the product, in line with the fan outlet. Also

clean this compartment with a vacuum cleaner by inserting the nozzle on the fan inlet hole.

Then clean the smoke exhaust, especially around the fittings, bends and any horizontal sections. For information on cleaning the flue,

contact a chimney sweeper.

ATTENTION: the frequency with which the smoke exhaust system must be cleaned depends on the use of the product

and the type of installation.

OTHER CHECKS

All the tightness gaskets fitted on the components subject to maintenance (smoke extraction fan, inspection sections, etc.) must be

replaced when these are removed for maintenance purposes. Verify the tightness of the gaskets on the hearth door and if necessary,

contact an authorised service centre for them to be replaced.

The company recommends contacting an authorised service centre for end-of-season maintenance and cleaning as the above-mentioned

operations will be performed together with a general inspection of the components.