MEDC XB10 User Manual
Page 4

12/11
© Cooper MEDC 2011
After cable termination has been completed, the PCB can be fully inserted into the enclosure, ensuring the
spacer on the bottom of the PCB snaps into the retaining clip on the boss inside the enclosure base. Be aware
of correct PCB orientation, illustrated by the label adhered to the inside wall of the enclosure body.
To replace the cover, use the same procedure as above but in reverse manner, ensuring the O-ring is in good
condition and fitted in the correct location at the top of the cover threads. Ensure the cover is screwed down tightly
and that there is no damage to the thread surfaces or mating faces of the cover and enclosure. There should be
a maximum gap of 0.2mm between the faces of the cover and enclosure to ensure correct o-ring compression.
Exde Unit
Unscrew and remove the 2 off M5 screws (4.0mm A/F hexagon key) and lift the Exe cover away from the
base of the unit
Terminate the field wiring as shown on the wiring diagram supplied with the unit.
Not more than one single or multiple strand lead shall be connected into either side of any terminal, unless
multiple conductors have been joined in a suitable manner, e.g. two conductors into a single insulated crimped
boot lace ferrule.
Leads connected to the terminals shall be insulated for the appropriate voltage and this insulation shall extend
to within 1mm of the metal of the terminal throat
All terminal screws, used and unused, shall be fully tightened down
Conductive metalwork (inc. cable glands) must be a minimum of 5mm away from the terminals
After cable termination has been completed, replace the Exe cover onto the enclosure, ensuring there is no
damage to the mating faces and that the O-ring is correctly seated in its groove to maintain the IP rating of
the unit. Replace and tighten the 2 off M5 cover screws (4.0mm A/F hexagon key). DO NOT over tighten
the cover screws as this may cause damage to the unit.
3.0 OPERATION
The operating voltage of the unit is stated on the unit label. The beacon can be powered directly or initiated
via a telephone ringing signal, depending on electronic configuration supplied.
GENERAL ARRANGEMENT
Ex de VERSION
Ex e COVER SCREWS
2 POSITIONS
58±2mm
Ø
123.5±2mm
45°±0.5°
357±5mm
GLAND ENTRY
2 POSITIONS
84±2mm
85±2mm
50±2mm
35±1mm
17.5±1mm
FIXING HOLE
Ø
4.5±1mm
3 POSITIONS
299±4mm
227
±2mm
Ø
122±2mm
95±2mm
37±1mm
DO NOT OVER-TIGHTEN SCREWS
Exe TERMINAL CHAMBER
Ex d VERSION