Jumper selection, Seismic detector, 11 en – RISCO Group SEISMIC Detector RK66S User Manual
Page 11: Jumper function, Figure 4: schematic of eol resistors
Advertising

Seismic Detector
11
EN
JUMPER SELECTION
Jumper
Function
S.A (Stand Alone) /BUS
J12
Used to enable tamper indication during Stand Alone
or BUS mode.
Stand Alone mode (Default).
BUS connection mode.
(See RISCO system
programming manuals).
J13: Alarm EOL
J15: Tamper EOL
Jumpers J13 and J15 allow for the selection of Alarm
and Tamper resistance (1K, 2.2K, 4.7K, 5.6K and
6.8K) according to the control panel. Follow the
terminal block connection diagram in Figure 4 when
connecting the detector to a Double End Of Line
(DEOL) zone.
Figure 4: Schematic of EOL Resistors
Panel DEOL
TAMPER
ALARM
C NC
TAMPER
NO
RESISTOR
(Default)
1K
2.2K
4.7K
5.6K
6.8K
TAMPER EOL JUMPERS (J15)
NO
RESISTOR
(Default)
1K
2.2K
4.7K
5.6K
6.8K
ALARM EOL JUMPERS (J13)
Advertising