Specifications, Certifications: ordering information – RISCO Group SEISMIC Detector RK66S User Manual
Page 14

Seismic Detector
14
Specifications
In order to continue improving the product, RISCO Group reserves the right to
change specifications and/or designs without prior notice.
Certifications:
Ordering Information
Model
Description
RK66S Seismic
Detector
Coverage
Up to 5 meters (16 feet) radius
Operating voltage
9 to 16 VDC
Current consumption
Typically 20mA @ 12VDC
RFI immunity
•
According to EN50130-4
Alarm contacts
24VDC, 0.1A, N/C and N/O
Tamper contacts
24VDC, 0.1A
Alarm contact hold time
2.5 seconds
Operating temperature
-40°C to +70°C (-40°F to 158°F)
Storage temperature
-50°C to +70°C (-58°F to 158°F)
Ingress protection (IP) rating
IP43
Impact Rating
IK08
RFI immunity
According to EN50130-4
Dimensions (L x H x W)
102 X 27.5 X 80.2 mm
(4.0” X 1.1” X 3.2”)
Weight
220 g ( 7.7 oz)
Supervision Time
15 min. for 868.65 MHz /
65 min. for 433.92 MHz