LightSYS Quick User Guide

Indicators:

(Power):

On: Power OK, No troubles
Off: No power
Rapid Flash

:

System trouble

(Ready):

On: Ready to arm
Off: Not ready to arm
Slow Flash: Ready to arm
with open Exit/Entry zone

(Arm) / RED LED

On: System armed
(Away or Stay)
Off: System disarmed
Slow Flash: System is in
Exit Delay
Rapid Flash

:

Alarm

(Tamper) :

On: Tamper alarm
Off: No tamper alarm

( Stay / Bypass):

On: System armed at Stay /
Bypass zones in the system
Off: No bypass zones

(Fire):

On: Fire alarm
Off: No fire alarm
Flash: Fire trouble

Edit User Code

1. From the main display press

.

2. Enter master code (default code 1234) followed by

.

3. Scroll to the option Codes/Tags >

.

4. Scroll to Define and press

.

5. Select a user and press

.

6. Select Edit Code and press

.

7. Enter the new code followed by

.

8. To edit user label scroll to Edit Label and enter label.
9. Repeat the above steps for additional codes.

Assign Proximity Tag

1. Follow steps 1-5 of the Edit User Code above.

2. Select (Re)Write tag and press

.

3. Within 10 seconds, approach the proximity tag to the keypad.