Setting and changing system time and date, Sms control commands – RISCO Group LightSYS User Manual

Page 3

Advertising
background image

LightSYS Quick User Guide

3


Setting and Changing System Time and Date

1.

Press

and enter grand master code followed by

.

2.

Using the arrow keys, scroll to the option Clock and press

.

3.

The display will show Time & Date. Press

.

4.

Enter the correct time in 24-hour format and date. For entering the date use the

keys to move the cursor and the

/

key to toggle among the

choices.

5.

Press

to save your settings.

SMS Control Commands

Controlling the System through SMS
(Note: Available only if your LighSYS is equipped with the GSM module)
SMS Structure: [User Code][Command]
Full arm: [Code] A
Home Arm: [Code] H
Group Arm: [Code][G][Select Group
A/B/C/D])
Full Disarm: [Code] D
Partition Arm: [Code] A [Partition No.]
Partition Disarm: [Code] D [Partition

No.]

Bypass zone: [Code] B [Zone number]
Unbypass zone: [Code] UB [Zone number]
Activate Output: [Code] UOON [UO No.]
Deactivate Output: [Code] UOOFF [UO

No.]

Get system status: [Code] ST
Get SIM credit level: [Code] CR
Change FM number: [Code] FMPHONE

[FM serial number] NEW [New Phone
No.)

Examples:

To arm the system send SMS: 1234A
To arm partition 1 and 2 send SMS: 1234A12
To disarm partition 1 send SMS: 1234D1

Notes:

1. Command words are not case sensitive (they can contain both capital, small or mixed letters).
2. A separator between command words is not required, although it is accepted.
3. Default grand master code is 1234.

Advertising