Warning, Caution – Subaru Robin RGX2900 User Manual

Page 20

Advertising
background image

ENGLISH

FRANÇAISE

ESPAÑOL

- 15 -

NOTE :

When the AC circuit breaker turns off during operation, the generator is over loaded
or the appliance is defective. Stop the generator immediately, check the appliance
and / or generator for overloading or detect and have repaired as necessary by
SUBARU Industrial Power Products dealer or service shop.

■

To take power out from the TWIST
LOCK RECEPTACLE, insert the
plug into the receptacle, and turn it
clockwise to the lock position.

■

Be sure to ground the generator if
the connected electrical device is
grounded.

TWIST

Style

Ampere

Receptacle

AC plug

Description

up to 20A

NEMA

5-20R

NEMA

5-20P

GFCI (Ground Fault
Circuit Interrupter)
Receptacle,
duplex(REC1)

up to 20A

NEMA

L14-20R

NEMA

L14-20P

Locking
Receptacle(REC2)

up to 30A

NEMA

L5-30R

NEMA

L5-30P

Locking
Receptacle(REC3)

up to 30A

NEMA

L14-30R

NEMA

L14-30P

Locking
Receptacle(REC4)

TABLE 1

WARNING

The duplex 120V receptacle is protected by a GFCI (Ground Fault Circuit
Interrupter). GFCI shuts off the output current from the duplex 120V
receptacle when a ground fault occurs in the generator or the appliance.
Please note that other receptacles are not protected by GFCI.

[CAUTION]