STOPPING THE GENERATOR

(a) Turn off the power switch of the

electric equipment and unplug the cord
from receptacle of the generator.

(b) Turn the AC circuit breaker to the

“OFF” position.

(c) Allow the engine about 3 minutes to

cool down at no-load before stopping.

(d) Turn the Engine switch to the position

“OFF”.

(e) Close the fuel valve.

OIL SENSOR

(a) The oil sensor detects the fall in oil

level in the crankcase and automati-
cally stops the engine when the oil
level falls below a predetermined level.

(b) When engine has stopped

automatically, switch off generator's
AC circuit breaker, and check the oil
level.
Refill engine oil to the upper level as
instructed on page 6 and restart the
engine.

(c) If the engine does not start by usual

starting procedures, check the oil level.

OPEN

CLOSE

CLOSE

Oil sensor

ON

OFF

ON

OFF

ON

OFF