1 series connections, Series connections -13 – KEPCO KLN 750W Series, Firmware Version 1.60 to 1.6x User Manual

Page 33

Advertising
background image

KLN 750W 032614

2-13

parallel to increase the current: I

MAX (one unit)

x N

P

= I

MAX (parallel combination)

where N

P

= number

of units in parallel. Similarly, up to two units (including the master) can be connected in series to
increase the voltage: E

MAX (one unit)

x N

2

= E

MAX (Series combination)

where N

2

= number of units in

series.

2.8.1

SERIES CONNECTIONS

Two identical KLN 750W units can be operated in series to double the output voltage.

CAUTION: TOTAL VOLTAGE MUST NOT EXCEED 600V TO AVOID DAMAGING THE

UNITS.

See Figure 2-10 for series connections without local sensing and Figure 2-11 for series connec-
tions with remote sensing. See PAR. 3.4.1 for operating units connected in series.

FIGURE 2-10. SERIES CONNECTIONS WITHOUT REMOTE SENSING

FIGURE 2-11. SERIES CONNECTIONS WITH REMOTE SENSING

2.8.1.1

SERIES CONNECTIONS USING OPTIONAL SERIES CONNECTION KIT

Connections for two identical KLN 750W units operated in series to double the output voltage
can be simplified by using the optional Series ConnectIon Kit (see Table 1-4).

CAUTION: TOTAL VOLTAGE MUST NOT EXCEED 600V TO AVOID DAMAGING THE

UNITS.

NOTE:
Adding local sensing wires
from + to +S and from – to –S
on both the Master and Slave
will make the front panel volt-
age reading slightly more
accurate (~10mV).