Conditions of conformance programming module – KEPCO MST 488 Programmer User Manual

Page 6

Advertising
background image

B

228-1372 COND/CONFORM 052704

Conditions of Conformance

Programming Module

When this product is used in applications governed by the requirements of the EEC, the following restric-
tions and conditions apply:

1.

For European applications, requiring compliance to the Low Voltage Directive, 73/23/EEC, this power
supply is considered a component product, designed for “built in” applications. Because it is incom-
plete in construction, the end product enclosure must provide for compliance to any remaining electri-
cal safety requirements and act as a fire enclosure. (EN61010-1:2001, Cl. 6, Cl. 7, Cl.8, and Cl. 9)

2.

This power supply is designed for stationary installation either within an equipment rack or a KEPCO
Rack Adapter RA 55 or CA 400.

3.

This power supply is considered a Class 1 (earthed) product. It is intended for use as part of equip-
ment meant for test, measurement and laboratory use, and is designed to operate from single phase,
three wire power systems. This equipment must be installed in a specifically designed KEPCO rack
adapter and within a suitably wired equipment rack, utilizing a three wire (grounded) mains connection.
See wiring section of this manual for complete electrical wiring instructions. (EN61010-1:2001,
Cl.6.10.1)

4.

This power supply has secondary output circuits that are considered SELV.

5.

This power supply employs a supplementary circuit protector in the form of a fuse mounted within its
enclosure. The fuse protects the power supply itself from damage in the event of a fault condition. For
complete circuit protection of the end product, as well as the building wiring, it is required that a pri-
mary circuit protection device be fitted to the branch circuit wiring. (EN61010-1:2001 Cl. 9.5)

6.

Hazardous voltages are present within this power supply during normal operation. All operator adjust-
ments to the product are made via externally accessible switches, controls and signal lines as speci-
fied within the product operating instructions. There are no user or operator serviceable parts within
the product enclosure. Refer all servicing to qualified and trained Kepco service technicians.