RA 19-7B 011409

2-1

SECTION 2 - INSTALLATION

2.1

UNPACKING AND INSPECTION

This equipment has been thoroughly inspected and tested prior to packing and is ready for
operation. After careful unpacking, inspect for shipping damage before attempting to operate. If
any indication of damage is found, file an immediate claim with the responsible transport ser-
vice. See Table 2-1 for a list of equipment supplied.

2.2

CONFIGURING THE RACK ADAPTER

Prior to installation the rack adapter must be configured by the user. Configuration consists of
the following:

• For configurations that use multiple output voltages it is possible to key the rack adapter

to accept only a power supply with corresponding keying (see PAR 2.3).

• Configuring slots for independent, parallel, or series operation. This can be done by

means of internal DIP switches, or externally by wiring the associated I/O mating con-
nector and DC OUTPUT terminals (see PAR. 2.4).

2.3

RACK ADAPTER KEYING INSTRUCTIONS

Series RA 19-(X)B rack adapters incorporate a keying mechanism to prevent accidental inser-
tion of the incorrect model HSF power supply into any position. The HSF power supplies are
keyed by voltage at the factory. The keying mechanism will prevent engagement of any of the
HSF power supply's connectors with those on the rack adapter's back plate unless the key and
keyway align. The user can configure each power supply position of the rack adapter for the
desired voltage in the desired position (see Figure 2-1). First gain access to the interior compo-
nents (PAR.2.3.1), then position the key as required (PAR. 2.3.2).

NOTE: After removing the rear panel, the keying pins can be accessed through the front of the

rack adapter, although it is recommended that the back plate be removed to gain easy
access to interior components.

2.3.1

DISASSEMBLY TO GAIN ACCESS TO INTERIOR COMPONENTS

NOTE: All power supplies must be removed prior to disassembly.

1. Remove eight spacers securing the four I/O connectors to the rear panel

TABLE 2-1. EQUIPMENT SUPPLIED

ITEM

QUANTITY

PART NUMBER

Rack Adapter

1

RA 19-7B

I/O Connector (Mating)

4

142-0449

Line cord (115 V a-c, 15A max, North American style plug, 6 ft)

2

118-0506

Instruction Manual

1

243-0890

Keying pins

8

108-0305

Hood for I/O Connector (Mating) P/N 142-0449

4

108-0204

Advertising