2.4.2.2.2 PARALLEL CURRENT SHARE - EXTERNAL WIRING

The Current Share lines for each supply must be connected in parallel at the I/O mating connec-
tor (pin 4) using external wiring (see Figure 2-6). Figure 2-6 is a simplified diagram of a typical
parallel configuration using external wiring at the I/O mating connector. Only slots 1, 4, 5, and
7 can be configured for parallel operation using external wiring. Position 5 of the associated
DIP switch must be set to OFF (open).

FIGURE 2-6. PARALLEL OUTPUTS USING EXTERNAL WIRING, TYPICAL

CONFIGURATION, SIMPLIFIED DIAGRAM