Input/output signals, 2 input/output signals – Emerson MICRO MOTION 1700 User Manual

Page 114

Advertising
background image

10.2

Input/output signals

Input/output signals – Model 1700 transmitter with analog outputs

Table 10-2:

Type

Description

Output variables

•

Mass flow

•

Volume flow

Inputs/outputs

•

One active 4–20 mA output

•

One active frequency output

HART

•

Bell 202 signal is superimposed on the primary milliamp out-
put

•

WirelessHART available via THUM adapter

Input/output signals – Model 2700 transmitter with analog outputs

Table 10-3:

Type

Description

Output variables

•

Mass & volume flow

•

Net product content / flow

•

Temperature

•

Density

•

Concentration

Inputs/outputs

•

Not intrinsically safe

•

One active 4–20 mA output

•

One active frequency output

•

Frequency output can be configured as a discrete output

HART/WirelessHART

•

Bell 202 signal is superimposed on the primary milliamp out-
put

•

WirelessHART available via THUM adapter

•

HART communication is unavailable on Foundation fieldbus
and PROFIBUS-PA transmitter versions

Input/output signals – Model 1700 transmitter with intrinsically safe
outputs

Table 10-4:

Type

Description

Output variables

•

Mass flow

•

Volume flow

Inputs/outputs

•

One passive 4–20 mA output

•

One active frequency output

HART

•

Bell 202 signal is superimposed on the primary milliamp out-
put

•

WirelessHART available via THUM adapter

Specifications

110

Micro Motion

®

Model 1700 and 2700

Advertising