Emerson MICRO MOTION 1700 User Manual
Page 46

Cross-section of assembled cable gland with cable
Figure 4-12:
A
B
C
D
E
F
G
A
A. Cable
B. Sealing nut
C. Seal
D. Compression nut
E. Braided shield
F. Brass compression ring
G. Nipple
9.
Remove the junction box cover and core processor end-cap.
10.
At both the sensor and transmitter, connect the cable according to the following
procedure:
a. Insert the stripped end of each wire into the corresponding terminal at the
sensor and transmitter ends, matching by color (see
should remain exposed.
Note
For ELITE
®
, H-Series, T-Series, and some F-Series sensors, match the wire to the terminal
by the color identified on the inside of the sensor junction box cover.
Sensor and transmitter terminal designations
Table 4-6:
Wire color
Sensor terminal
Transmitter terminal
Function
Black
No connection
0
Drain wires
Brown
1
1
Drive +
Red
2
2
Drive –
Orange
3
3
Temperature –
Yellow
4
4
Temperature return
Green
5
5
Left pickoff +
Blue
6
6
Right pickoff +
Violet
7
7
Temperature +
Mounting and sensor wiring for 9-wire remote installations
42
Micro Motion
®
Model 1700 and 2700