Amprobe ACD-4 Mini-Clamp-DMM User Manual

Page 12

Advertising
background image

7

Storage temperature:

-20 to +60°C (-4°F to 140°F), 0 to 80% RH

(batteries not fitted).

Overvoltage category:

IEC 61010-1 600V CAT.Ⅲ.

CAT

Application field

The circuits are not connected to mains.

The circuits are directly connected to Low-voltage installation.

The building installation.

The source of the Low-voltage

installation.

Operating altitude:

2000m (6562 ft)

Conductor Size:

27mm (1.06 in) diameter.

Pollution degree:

2

EMC:

EN 61326-1

Shock vibration:

Sinusoidal vibration per MIL-T-28800E

(5 ~ 55 Hz, 3g/0.007lb maximum).

Drop Protection:

4 feet drop to hardwood on concrete floor.

Dimensions (W x H x D): 56mm x 188mm x 28mm

(2.2 in x 7.4 in x 1.1 in)

Weight:

225g (0.5 lb) including battery.

Accessories:

Battery (installed), Carrying case, Test lead

and User manual.

Electrical Specifications

Accuracy is ±(% reading + number of digits) at 23°C ± 5°C (73.4°F ± 41°F)

<

80%

RH.

Temperature coefficient: Add 0.2 x (Specified accuracy) / °C,

< 18°C (64.4°F), > 28°C (82.4°F).