9

Overload protection:

600V rms

Open circuit Voltage:

-1.3V approx.

* 1 < 100 dgt rolling.
* 2 < 10 dgt rolling.
* 3 The maximum LCD reading is 1400 counts.

Continuity

Internal beeper activates if the resistance of the circuit under test is less than
20e. It will then turn off if the resistance is increased beyond 50e. Response

time is approximately 50m sec.

Overload protection:

600V rms.

- EMC: EN61326-1.

This product complies with requirements of the following European
Community Directives: 89/ 336/ EEC (Electromagnetic Compatibility) and 73/ 23/
EEC (Low Voltage) as amended by 93/ 68/ EEC (CE Marking). However, electrical
noise or intense electromagnetic fields in the vicinity of the equipment may
disturb the measurement circuit. Measuring instruments will also respond to
unwanted signals that may be present within the measurement circuit. Users
should exercise care and take appropriate precautions to avoid misleading
results when making measurements in the presence of electronic interference.

MAINTENACE

If there appears to be a malfunction during the operation of the meter, the
following steps should be performed in order to isolate the cause of the
problem.

1. Check the battery. Replace the battery immediately when the “N

symbol appears on the LCD.

2. Review the operating instructions for possible mistakes in operating

procedure.

Except for the replacement of the battery, repair of the meter should be
performed only by a Factory Authorized Service Center or by other qualified
instrument service personnel. The front panel and case can be cleaned with
a mild solution of detergent and water. Apply sparingly with a soft cloth and
allow to dry completely before using. Do not use aromatic hydrocarbons or
chlorinated solvents for cleaning. If the meter is not to be used for periods of
longer than 60 days, remove the batteries and store them separately

Do not attempt to repair this Meter. It contains no user-serviceable parts.
Repair or servicing should only be performed by qualified personnel.