8

OL Protection: 600 V ac rms

AC Amp (50/60 Hz)
Ranges:

RS-1007 Pro: 15 / 40 / 100 / 300 / 1000 Arms
RS-3 Pro: 6 / 15 / 40 / 100 /600 Arms

Accuracy: ± 3 % of Full Scale

Ohms
Range: 1000 ohms
25 Ohms mid-scale
Accuracy: ± 3 degrees of Arc
Open Circuit voltage: 1.5v
Short circuit Current: 58 mA
OL Protection: (F 0.5 A / 1000 V, size 6 x 32 mm IR fast blow ceramic)