SPECIFICATIONS
General Specifications

Display :

2000 counts.

Polarity Indication :

Automatic, positive implied, negative

indicated.

Overrange Indication : “OL” or “-OL”.
Batteries Life :

Alkaline 250 hours

Low Batteries Indication : “N” is displayed when the batteries voltage

drops below operating voltage.

Auto Power Off :

Approx 10 minutes.

Operating Ambient :

Non-condensing ≦50°F, 51.8°F ~ 86°F

(≦80% R.H) 87.8°F ~ 104°F (≦75% R.H),

105.8°F ~ 122°F (≦45% R.H)

Storage Temperature : -4°F to 140°F , 0 to 80% R.H. when battery

removed from Meter.

Temperature Coefficient : 0.15 x (Spec. Accy) /°F ,< 64.4°F or >

82.4°F.

Measure :

Samples 2 times per second nominal.

Altitude :

6561.7 ft (2000m)

Safety :

Complies with EN61010-1, UL61010-1,

IEC 61010-1,

V/e :

CAT.III. 600V, CAT.II. 1000V.

A :

CAT.III. 500V

Pollution degree :

2

Power Requirements : 1.5V x 2 IEC LR03, AM4 or AAA size
Dimensions (W x H x D) : 74mm (2.9”) x 156mm (6.1”) x 44mm (1.7”)
Weight :

320g (0.71lb) including battery.

Accessories :

Battery (installed), Test leads and user manual.

Electrical Specifications

Accuracy is ±(% reading + number of digits) at 23°C ± 5°C < 80%RH.