Amprobe AM-60 Compact-Digital-Multimeter User Manual

Page 14

Advertising
background image

9

DC / AC Volts

Range

AC Accuracy

200.0mV *

Unspecified

2.000V *

±(1.5%+5dgt) 50Hz ~ 300Hz

20.00V ~ 200.0V *

±(1.5%+5dgt) 50Hz ~ 500Hz

750V AC / 1000V DC

DC Accuracy :

±(0.5% + 2dgt)

Over voltage protection : 1000V DC or 750 V ACrms.
Input Impedance :

10Me // less than 100pF.

* CMRR / NMRR :

(Common Mode Rejection Ratio)

(Normal Mode Rejection Ratio)

V

AC

:

CMRR > 60dB at DC, 50Hz / 60Hz

V

DC

:

CMRR > 100dB at DC, 50Hz / 60Hz

NMRR > 50dB at DC, 50Hz / 60Hz

AC Conversion Type :

Average sensing rms indication.
AC conversions are ac-coupled, true rms responding,
calibrated to the sine wave input.
* The minimum LCD reading is 1400 count in Auto Ranging Mode.
Crest Factor : C.F. = Peak / Rms
+ 1.5% addition error for C.F. from 1.4 to 3
+ 3% addition error for C.F. from 3 to 4

DC / AC Current

Range

DC Accuracy

AC Accuracy

Voltage

Burden

2.000A

±(1.0% + 3 dgt)

±(1.5% + 5 dgt)

50Hz ~ 500Hz

*

2V max

10.00A **

Overload Protection :

A input : 10A (500V) fast blow fuse

Advertising