Amprobe AMB-50 Insulation-Resistance-Tester User Manual

Page 16

Advertising
background image

10

SPECIFICATIONS

Safety and Compliances

Certification

Compliances

IEC 61010 CAT.III 600V overvoltage and double insulation standard

Physical Specifications

Display (LCD)

Digital: 1999 counts
Analog bar graph.

Operating Temperature

0°C~40°C (32°F ~104°F )

Storage Temperature

-20°C ~60°C (-4 °F~152°F )

Relative Humidity

85% @ -10°C ~40°C below;
90% @ 0°C ~40°C :

Battery Type

8pcs X 1.5V (LR14) batteries or power adaptor (input voltage 230V, 50/60Hz,
75mA, input DC14V, 1.0A).
Power adaptor is not included

Dimensions (H x W x L)

202 x 155 x 94 mm

Weight

Approx. 2kg (4.4 Lbs) (including battery)

General Specifications

Range

Auto

Overloading

Display OL on insulation resistance range

Battery Indicator

Display

Icon Display

Equips with function and battery indicator icons.

Current Consumption

Maximum: around 1.0A
Average: around 20mA

Feature Summary

Display Backlight

Bright backlight for clear readings in poorly lighted areas.

Computer connection

Via USB interface.

Data Logging and Recall

18

Autorange

The Meter automatically selects best range

Warning

and red light will on.

Voltage

Auto release voltage

COMP Measurement

Use the Compare function to set a pass/fail compare level for the insulation
measurements.

PI Measurement

Polarization Index is the ratio of insulation resistance. You can pre-set two point
of times and automatically carry out the measurement.

TIME

To carry out measurement by setting a specified time within 15 minutes.

Advertising