Amprobe VPC-30 VPC-31 Voltage-Continuity User Manual

Page 13

Advertising
background image

7

Audible Continuity Function

Refer to Fig.4

Short the two test probes together for continuity function check as described
in Indicator Self-Test section. The continuity LED turns on together with a
continuous beep tone indicates a complete circuit is being detected via the test
probes. Audible-Continuity is convenient for checking wiring connections and
operation of switches.

Auto Power On & Auto Power off (APO)

The tester turns on automatically and is ready for measurement within
1 second (> 7 seconds on ACV “wake-up” measurement) when making
significant measurement or push button activity. Allow this delay on the
“wake-up” measurement. Wake up the tester by shorting the two test probes
together before making ACV measurements can improve the “wake-up”
delay. The meter turns off automatically (APO) to extend battery life after
approximately 25 seconds of no significant measurement or push button
activity.

MAINTENANCE

WARNING!

To avoid electrical shock, disconnect the tester from any circuit and

remove the test probes from the input jacks before opening the case

and/or the battery access door. Do not use the tester with open case and/

or the battery access door. Do not attempt to repair this unit. It contains

no user-serviceable parts. Unauthorized persons shall not disassemble

the tester.