Specifications general specifications – Amprobe VPC-30 VPC-31 Voltage-Continuity User Manual

Page 15

Advertising
background image

9

SPECIFICATIONS
General Specifications

Display: 3 digits 1000 counts
Update Rate: 5 per second nominal
Operating Temperature: -10˚C ~ 55˚C (14˚F~131˚F)
Relative Humidity: 20% ~ 96%
Altitude: Operating below 2000m
Storage Temperature: -10˚C ~ 55˚C (14˚F~131˚F), 20% ~ 96% R.H. (with battery

removed)
Temperature Coefficient: Nominal 0.15 x (specified accuracy)/ ˚C @ (-10˚C ~ 18˚C or

28˚C ~ 55˚C), or otherwise specified
Sensing: Average sensing
Measurement Category: CAT III 1000V & CAT IV 600V AC & DC
E.M.C.: Meets EN61326-1:2006 (EN55022, EN61000-3-2, EN61000-3-3, EN61000-4-

2, EN61000-4-3, EN61000-4-4, , EN61000-4-5, EN61000-4-6, EN61000-4-8, EN61000-

4-11):
For both models: Performance is specified in an RF Field of 3V/m. Performance

above 3V/m is not specified.
For VPC-31 LCD display only: In an RF Field of 3V/m, total accuracy = Specified

accuracy + 45d. Performance above 3V/m is not specified
Type of Protection: IP65
Pollution Degree: 2
Safety: Meets EN61010-1 and IEC61010-1 2nd Edition to CAT III 1000V & CAT IV

600V
Transient Protection: 8kV lightning surge (1.2/50μs)
Overload Protection: 1000VDC & VAC rms
Low Battery: Below approx. 2.4V; Below approx. 2.6V with shaker ON
Power Supply: Standard 1.5V AAA Size (NEDA 24G or IEC R03) battery X 2; or

1.5V AAA Size (NEDA 24A or IEC LR03) alkaline battery X 2
APO Timing: Idle for 25 seconds
Power Consumption (typical): 3mA at Power-on ready; 25mA at 1000VAC full

LED indication. 75mA at 1000VAC with shaker ON
APO Consumption (typical): 10μA
Dimension: 233 x 57 x 40mm (9.17 x 2.24 x1.57 IN)
Weight: Approx. 220 g (0.485 lb)
Special Features: High Input Impedance, Indicator Self-Test, Auto-Hold, Overload-

Alert Warning, EF-Detection, AC-Detection Shaker, Bi-Color LED Hazardous Live

Warning, and GFCI Trip Test (VPC-31 only)

Advertising