MAINTENANCE

No normal maintenance apart from battery replacement is necessary

with your Amprobe Tic Tracer. Replace the battery when no signal is

heard when the instrument is switched ON.

Battery Replacement

1. Slide the small latch on the top of the battery compartment

downward.

2. Tilt out and remove the battery cover.

3. If applicable, disconnect old battery from the connector.

4. Connect a new, and/or tested, 9V battery to the connector,

and replace in compartment.

5. Replace cover and move latch upwards to secure.

SPECIFICATIONS

Power Supply: 9 VDC battery

Voltage Detection Range:

TIC 300CC

30 to 1500 VAC

TIC 300HV

Low – 30 to 1500 VAC

High – 1500 to 122,000 VAC *

*Use only with proper safety equipment and Hot Stick Amprobe

Model TIC 410A for voltages up to 122kV.

Operating Temperature Range: 32°F to 125°F (0°C to 52°C)

Battery Life: Approximate Battery shelf life

Duty Cycle: Continuous

Response Time: Instantaneous

Dimensions: 8.5 x 2.8 x 1 inches (21.6 x 7 x 2.5 cm)

Weight: 5 ounces (140 gr)