Chapter 2: Hardware and Software Setup

Syncro CS Cluster-in-a-Box Hardware Setup

4.

Place the Syncro CS controller on a flat, clean, static-free surface after grounding yourself.

NOTE

If you want to replace a bracket, refer to the Replacing Brackets on
MegaRAID SAS+SATA RAID Controllers Quick Installation Guide
for
instructions.

5.

Take the cable included with the kit and insert the smaller of the two 6-pin cable connectors on the cable into the
6-pin connector on the remote CVPM02 module, as shown in the following figure.

Figure 3 Connecting the Cable to the Remote CVPM02 Module

6.

Mount the CVPM02 module inside the CiB enclosure, based on the location and the type of mounting option.

J6B4

Onboard Serial UART connector

Reserved for LSI use.

J6B5

Global Drive Fault LED indicator

2-pin header

Connects to a single LED that indicates drive activity on
either port.

J6B6

Onboard Serial UART connector

Reserved for LSI use.

Table 1 Syncro CS 9271-8i Controller Jumpers and Connectors (Continued)

Jumper/

Connector

Type

Description

3_01851-00

J2B1

CVPM02

Module

CVFM02

Module