DUCTING REQUIREMENTS

Recommended

Use only for short-run

installation

Weather Hood

Type

4" DIA

4" DIA

4"

4 inch. (10.2 cm)

4" DIA

2-1/2"

2.5 inch. (6.4 cm)

No. of 90°
elbows

Rigid Metallic

Rigid Metallic

0

90 ft. (27.4 m)

60 ft. (18.3 m)

1

60 ft. (18.3 m)

45 ft. (13.7 m)

2

45 ft. (13.7 m)

35 ft. (10.7 m)

3

35 ft. (10.7 m)

25 ft. ( 7.6 m)

Manometer measurements

The static pressure in any exhaust system for best results shall be between
0.3 to 0.8 inches of water column, and cannot be less than 0 under any

circumstances. with installed duct of 4 inch diameter. Measurement must

be done with the empty dryer working with a manometer at the point
where the exhaust duct connects to the dryer. A no-heat setting should be
used. Lint filter must be clean.

If this new dryer is installed into an existing exhaust system you must make

sure:

•

The exhaust system meets all local, state, and national codes.

•

That a flexible plastic duct is not used.

•

To inspect and clean all lint buildup from inside the existing duct.

•

The duct is not dented or crushed.

•

The exhaust hood damper opens and closes freely.