WARNING

The correct exhaust installation is YOUR RESPONSIBILITY.

•

Use a 4-inch (10.2cm) diameter rigid aluminum or rigid galvanized

steel duct.

•

Do not use smaller diameter than recommended diameter duct.

•

Ducts larger than 4 inches (10.2cm) in diameter can result in

increased accumulation of lint and changes in performance

•

Lint should be removed from internal filter before every cycle and

clean ducts periodicly.

•

If a flexible metal duct must be used, use the type with a stiff sheet

metal wall. Do not use a flexible duct with a thin foil wall. A serious

blockage can result if the flexible metal duct is bent too sharply.

•

Never install any type of flexible duct in walls, ceilings, or other

concealed spaces.

•

Keep the exhaust duct as straight, short as possible, minimum elbows

•

Secure joints with duct tape. Do not use screws.

•

Plastic flexible ducts can kink, sag, be punctured, reduce airflow,

extend drying times, and affect the dryer operation.

•

Exhaust systems longer than recommended 90 ft can extend drying

times, affect machine operations, and collect lint.

•

The exhaust duct should end with an exhaust hood with a swing-out

damper to prevent back drafts and entry of wildlife. Never use an

exhaust hood with a magnetic damper.

•

The hood should have at least 12 inches (30.5cm) of clearance

between the bottom of the hood and the ground or other

obstruction. The hood opening should point down.

•

Never install a screen over the exhaust outlet.

•

To avoid lint buildup, do not exhaust the dryer directly into a window

well. Do not exhaust under a house or porch.

•

If the exhaust duct must run through an unheated area, the duct

should be insulated and slope slightly down towards the exhaust

hood to reduce condensation and lint buildup.

•

Inspect and clean the interior of the exhaust system at least once a

year. Unplug the power cord before cleaning.

•

Check frequently to make sure the exhaust hood damper opens and

closes freely.

•

Check once per month, and clean at least once per year. NOTE:

If your clothes are not getting dry, then check the ducting for

obstructions.

•

Do not exhaust the dryer into a wall, ceiling, crawl space, or

concealed space of a building, gas vent, or any other common duct

or chimney. This could create a fire hazard from the lint expelled by

the dryer.

•

Do not use non-metallic flexible duct.

•

To reduce the risk of fire, this dryer MUST BE EXHAUSTED

OUTDOORS without obstruction around the outlet.

Dry

er

Saf

ety

Oper

ation

R

equir

ements

P

arts and

F

eatur

es

Ins
tallation

Ins
tructions

Dry

er Use

A

p

p

e

nd
ix

Dry

er Car

e

T

ro

u

b

le

sh

o

o

tin

g

13

Advertising