11. INFORMATION AND FAULT MESSAGES

11.1 Acoustic signals

Beep sound

end of charging or discharging

Double beep

energy demand above or below energy control setting via

RFS 2.1 / RFS 2.2

transmitter

11.2 Message in display

Fault 1
(F1)

No flash on release

Is the ignition wire correctly connected? Is the flash tube correctly installed?

Otherwise replace flash tube

Fault 2
(F2)

Afterglow

Switch the unit off and then on again. If this fault occurs repeatedly, the flash tube

is defective

Fault 3
(F3)

Electronic defect

Unit must be sent to Service for repair

Fault 4
(F4)

Over-voltage in flash capacitor

Unit must be sent to Service for repair

Fault 5
(th)

Thermal alarm, capacitors overheated

A cooling phase of approximately 20 minutes is started. Do not switch the unit off!

* Error messages are always also indicated by the red cognition light

12. FAQS

12.1 Changing flash tubes

1) Switch the unit off and remove the battery.

2) Wait for one minute for the flash capacitor to discharge. Remove the safety glass by pulling it

out of its retaining clips.

3) Press the contact spring downwards and pull the flash tube out carefully.

1)

2)

3)

21

12.2 Changing light shapers

1) Turn the light shaper in either direction to its stop.

2) Pull the release backwards and, at the same time, turn the light shaper until it is free of the

bayonet fitting.

3) Remove the light shaper carefully to the front. Take care not to damage the safety glass.

1)

2)

3)

12.3 Mounting an umbrella

Insert the umbrella in the opening provided beneath the unit.