2. INITIAL COMMISSIONING

1. Remove the protective cover

2. Press the “on / check” button

3. Install the battery

4. Switch the unit on at the main switch

11

3. CONTROL ELEMENTS

Element

Function

Rotary controller (1)

Switches the unit on and off (stand-by mode). Pressing
the rotary controller for 3 s switches the unit to standby

In menu: menu navigation and confirmation of menu
items. There is an explanation of menu navigation
in Section 5

In operation: changes the flash energy. Turning anti-
clockwise reduces the flash energy, turning clockwise
increases it. Turning slowly changes it in 1/10 th.
f-stop steps, turning fast (“twisting”) in 1/1 f-stop steps

Info display (2)

Shows the flash energy selected, or the menu options

Mod / Eco on / off (3)

A short press switches the modelling light on or off
A long press switches between Normal and Eco modes

test

Test initiation (4)

Test initiation: the “ready” display around the rotary

controller changes to blue as soon as the charge /
discharge operation has been completed. A long press
switches the unit back to the default settings

Menu function

speed

Speed (5)

For fast charging and flash times. See explanation
in Section 7

WiFi

WiFi (6)

Shows whether WiFi is switched on or off

HS

HS

(7)

Indicates whether

HS

is switched on or off

st/ch

Studio / Channel (8)

Is the menu item for selecting the current studio channel
(

RFS 2

)

lamp

Lamp (9)

Is the menu position to select a certain lamp channel
(

RFS 2

)

seq

Sequence (10)

Is the menu position to select a certain number
of flashes

beep

Beep (11)

Shows if the acoustic “ready” warning is switched
on or off

sync

Sync (12)

Permits the selection of different methods of release
(photocell, radio, photocell and / or radio)

Sync socket / Micro

USB

(13 / 14)

For release via the sync cable, or software update
via Micro

USB

On / Off (15)

To switch the unit on and off. After switching the unit on,

it is only possible to switch it off again after a delay
period of 4 seconds