Fj200 strobe: warnings – Westcott FJ200 Strobe User Manual

Page 8

Advertising
background image

 

FJ200 Strobe: Warnings 

Caution 

●

IMPORTANT:

​

During operation, the flash tube, LED modeling lamp, and select components of 

the FJ200 strobe temperatures will increase. Please use caution while using to avoid serious 
burns or injuries. 

●

Use only with the Westcott FJ200 Lithium Polymer Battery and/or AC Power Adapter and Cord.  

●

Do not touch the flash tube, LED modeling lamp, metal reflector, metal snoot, and other metal 
components and accessories after immediate use to avoid potential injury. 

●

Never leave unattended around children and/or pets. 

●

Keep away from fire, water, and moisture. 

●

Do not submerge in water. 

●

Avoid drastic temperature changes before, during, or after use. 

●

Avoid direct skin contact with the flash tube and LED modeling lamp when replacing the flash 
tube. 

●

Always remove the FJ200 Lithium Polymer Battery from the FJ200 Strobe during travel/storage 
to avoid accidental operation which could lead to overheating or permanent damage. 

●

Do not overtighten the tilter bracket tension knob. 

●

Ensure the FJ200 is securely mounted before use. 

●

Only use FJ200 compatible modifiers and accessories and ensure they are securely attached to 
the FJ200 Strobe before use. 

●

Do not attempt to modify any Westcott products. Contact Westcott for assistance. 

●

The operating temperature range is 14-104°F (-10-40°C).  

 

Dual-Stage Heat Protection System 

The FJ200 is equipped with a self-monitoring system ensuring safe operation during continued 
full-power use during a short timeframe. The monitoring system provides a staged automatic shutoff 
scenario;  

●

Stage 1: Once the strobe reaches an internal operating temperature of 131°F (55°C) the screen will 
display a red [

​

Bulb Icon

​

] and the recycle time will increase to 2 seconds in efforts to cool the unit 

while allowing for further operation. 

●

Stage 2: Once the strobe reaches an internal operating temperature of 167°F (75°C) the screen 
will display a red

​

[OH]

​

icon and the unit will be inoperable for an estimated 10 minutes until an 

adequate internal temperature has been reached to continue operation. 

●

Once the unit has cooled, the [

​

OH]

​

will disappear from the screen and it will then be safe to 

continue operation.

 

7 

Advertising