Appendix 4: Firmware Upgrade

From time to time Datavideo may release new firmware to either add new SE-1200 MU features or to fix
user reported bugs in the current switcher firmware. Customers can update the switcher firmware
themselves if they wish, or they can contact their local supplier or Datavideo office for assistance, should
they prefer this method.

This page describes the firmware update process, and it should take

approximately 15 minutes total time

to complete

.

Once started

the update process should not be interrupted in any way

as this could result in a non-

responsive unit.

A working SE-1200 MU switcher requires the following:

A Windows 7/8/10 PC/Laptop

The latest Control Panel program for the SE-1200 MU. This can be obtained from your local
Datavideo office/supplier.

A simple router IP network/Static IP setup, see example in

Section 3.1.1

(Windows PC) /

3.2.1

(MAC).

Firmware Update Procedure

1.

Install the latest SE-1200 MU Control Panel program on the Windows PC/Laptop.

2.

Locate the Ethernet port on the rear panel of the SE-1200 MU and connect the

Ethernet port to the router.

3.

Open the SE-1200 MU Control Panel program.

4.

Locate and click the

Setup button

in the

MENU SELECT Panel

.

5.

Click the

Software Upgrade option

in the yellow menu column.

Windows PC Users

MAC Users


6.

Click the

Upgrade Processor option

in the lower menu row, the upgrading notification will appear.

7.

Wait for the SE-1200 MU to complete the upgrade process, the upgrade notification will disappear.

8.

Restart the SE-1200 MU device.

Note:

The update may reset the IP address to the factory defaults,

see

Section 3.1.2

(Windows PC) /

3.2.2

(MAC).

9.

Restart the SE-1200 MU Control Panel program on the Windows PC/Laptop.