4.7.4 Serial Communication

RS485 Setting

Camera ID: This entry is used to assign camera own ID code.

Baud Rate: This field is to set the speed at which is used to transmit instruction or

information through the RS485 port on the camera. There are six different speeds,

2400/4800/9600/19200/38400/57600. The default setting from the factory is 9600.

Protocol: Select protocol from EverFocus and Pelco-D. The default setting from the

factory is Pelco-D.

Data Bit: This field is the data bit at which you will be transferring. There are two

settings for this option: 8 or 7. The default is set to 8.

Stop Bit: This field is to set the stop bit for the RS485 connection. There are two

different stop bits, 1 or 2. The default is set to 1.

Parity: This field is to select the parity level at which you will be connected. You can

choose between None, Odd, or Even parity levels. Default is set to none.